12,054 research outputs found
Cine recording ophthalmoscope
Camera system provides accurate photographic recording during acceleration of centrifuge and permits immediate observation of dynamic changes in retinal circulation by a closed-circuit television loop. System consists of main camera, remote control unit, and strobe power supply unit, and is used for fluorescein studies and dynamometry sequences
Recommended from our members
Climate change Social divisions in belief and behaviour
As a global problem, climate change affects everyone. But within Britain opinion is divided. This chapter asks to what extent people in Britain believe humans cause climate change, think it is a problem, and feel that citizens and governments are likely to be able to reduce it. Also, what are the main social divisions in attitudes to climate change, and how much does opinion differ between supporters of different political parties
Preliminary evaluation of a liquid belt radiator for space applications
The liquid belt radiator (LBR) is discussed. The LBR system operates either in the sensible heat mode or in the latent heat mode. Parametric analysis shows that the LBR may reduce the mass of heat pipe radiators by 70 to 90% when the LBR surface has a total emissivity in excess of 0.3. It is indicated that the diffusion pump oils easily meet this criteria with emissivities greater than 0.8. Measurements on gallium indicate that its emissivity is probably in excess of 0.3 in the solid state when small amounts of impurities are on the surface. The point design exhibits a characteristic mass of 3.1 kg/kW of power dissipation, a mass per unit prime radiating area of approximately 0.9 kg/sq ms and a total package volume of approximately 2.50 cubic m. This compares favorably with conventional technologies which have weights on the order of 4 kg/sq m
Liquid belt radiator design study
The Liquid Belt Radiator (LBR) is an advanced concept developed to meet the needs of anticipated future space missions. A previous study documented the advantages of this concept as a lightweight, easily deployable alternative to present day space heat rejection systems. The technical efforts associated with this study concentrate on refining the concept of the LBR as well as examining the issues of belt dynamics and potential application of the LBR to intermediate and high temperature heat rejection applications. A low temperature point design developed in previous work is updated assuming the use of diffusion pump oil, Santovac-6, as the heat transfer media. Additional analytical and design effort is directed toward determining the impact of interface heat exchanger, fluid bath sealing, and belt drive mechanism designs on system performance and mass. The updated design supports the earlier result by indicating a significant reduction in system specific system mass as compared to heat pipe or pumped fluid radiator concepts currently under consideration (1.3 kg/sq m versus 5 kg/sq m)
Visual examination apparatus
An automated visual examination apparatus for measuring visual sensitivity and mapping blind spot location including a projection system for displaying to a patient a series of visual stimuli. A response switch enables him to indicate his reaction to the stimuli, and a recording system responsive to both the visual stimuli per se and the patient's response. The recording system thereby provides a correlated permanent record of both stimuli and response from which a substantive and readily apparent visual evaluation can be made
Visual sensitivity tester
Testing device uses closed loop film cassettes to project programmed visual stimuli on screen which the observer views through a lens making the stimuli appear to be at optical infinity. Tester is useful for determining changes in glautomatous visual field sensitivity
Visual examination apparatus
An automated visual examination apparatus for measuring visual sensitivity and mapping blind spot location is described. The apparatus includes a projection system for displaying to a patient a series of visual stimuli, a response switch enabling him to indicate his reaction to the stimuli, and a recording system responsive to both the visual stimuli per se and the patient's response. The recording system provides a correlated permanent record of both stimuli and response from which a substantive and readily apparent visual evaluation can be made
Study of highly fluorinated heterocyclic polymers for cryogenic bladder applications Final report, 15 Oct. 1968 - 15 Mar. 1970
Highly fluorinated heterocyclic polymers for cryogenic bladder application
The development of structural adhesive systems suitable for use with liquid oxygen /LOX/ Summary report, 20 Jun. 1969 - 19 Apr. 1970
Development of structural adhesive systems suitable for use with liquid oxyge
Development of nonflammable adhesives Final technical report, 17 Sep. 1968 - 20 Jan. 1970
Development of nonflammable fluorinated polyurethane adhesives for spacecraft system
- …